FIXED (GO/NO GO) CURRENT SENSORS

Building Automation
C-1200 - SENVA Mini Solid-Core-Adjustable Set Point Current Switch

Split-Core Auto Calibrating VFD Current Sensor .25-50A Range - 1A @ 30VAC/DC N.O. Output

The C-1200 fits in small starter enclosures usually associated with exhaust fans. Alignment issues are eliminated because it can hang directly on a wire with a screw mount or by using plug in iris. The polarity insensitive output eliminates wiring errors making it easy to wire. It is cost effective because of its reduced labor costs compared to differential pressure switches. Also, the C-1200 is less expensive than 277V relays for lighting status. There are no moving parts to fail because it is a 100% solid state making it extremely reliable. Also, it has an industry leading 7 year warranty.

Available with optional command relays.

List: $31.50

$12.00

Building Automation
C-1200HV - SENVA High Voltage Mini Solid Core-Go/No Go Current Switch

Split-Core Auto Calibrating VFD Current Sensor .25-50A Range - .2A @ 120VAC N.O. Output

The C-1200HV fits in small starter enclosures usually associated with exhaust fans. Alignment issues are eliminated because it can hang directly on a wire with a screw mount or by using plug in iris. The polarity insensitive output eliminates wiring errors making it easy to wire. It is cost effective because of its reduced labor costs compared to differential pressure switches.

Available with optional command relays.

List: $69.00

$28.00

Building Automation
C-1300 - SENVA Solid Core-Go/No Go Current Switch

Solid Core Go/No Go Current Switch .25-50A Range - 1A @ 30VAC/DC-N.O. Contact

The larger 1/2" diameter aperture accommodates spade terminals found in package units. The 250 mA turn-on is compatible with electronic commutated motors. It fits in smaller starter enclosures that are usually associated with exhaust fans. It is easy to wire because all of the confusion and errors that go along with wiring are eliminated with the polarity insensitive output. It is cost effective due to the reduced labor cost compared to differential pressure switches and is less expensive than 277V relays for lighting status. The 100% solid state makes it reliable because there are no moving parts to fail. It also has an industry leading 7 year warranty.

Available with optional command relays.

List:$36.00

$15.00

Building Automation
C-1200HV-240 Senva Mini Solid-Core Adjustable Set Point Current Switch

Mini Solid-Core 0.25A (on) ~ 50A (50A Max.) Output 0.2A @120/240VAC Max.

Key Points
• Go/No status
• 0.25-200A range
• Split and solid core models
• N.O. 30VAC/DC or 120VAC output
• Optional command relay
• UL/ULC, CE listed
• RoHOS compliant

Applications
• Monitoring on/off status of electrical loads
• Monitoring direct-drive units, exhaust fans, and other fixed loads
• Verifying lighting run times

Fixed threshold trip point detects the presence of current above low trip point to provide cost-effective status monitoring unit vents, exhaust fans, recirculation pumps, and other fixed loads where belt loss is not a concern.
Looking for cost-effective status? Our mini-solid core fits in the smallest enclosures. Our split-core is great for retrofit applications, plus you can snap on a serviceable command relay for controlling the load in a single device. Great for go/no status on resistive loads, unit-vent heaters, and more. NOTE: CR1 series command relay has been updated to CR3 and CR4 series.

List: $70.73

$34.20

Building Automation
C-2200 - SENVA Sub-Mini Split Go-no Fixed Set-point Mini Current Switch

Split-Core Go/No Go Current Sensor .50-50A Range - 1A @ 30VAC/DC N.O. Output

Fixed threshold trip point detects the presence of current above low trip point to provide cost-effective status monitoring unit vents, exhaust fans, recirculation pumps, and other fixed loads where belt loss is not a concern.


List: $63.00

$25.00

Building Automation
C-2300 - SENVA Split-Core-Go/No Go Current Switch

Split-Core Go/No Go Current Sensor .35-200A Range 1A @ 30VAC/DC N.O. Output

Fixed threshold trip point detects the presence of current above low trip point to provide cost-effective status monitoring unit vents, exhaust fans, recirculation pumps, and other fixed loads where belt loss is not a concern.

List: $51.00

$19.00

Building Automation
C-2300HV - SENVA High Voltage Split-Core-Go/No Go Current Switch

Split-Core Go/No Go Current Sensor .35-200A Range 0.2A@120VAC N.O. Output

Fixed threshold trip point detects the presence of current above low trip point to provide cost-effective status monitoring unit vents, exhaust fans, recirculation pumps, and other fixed loads where belt loss is not a concern.

List: $86.85

$34.00